LWIR – Long Wave Infrared Imaging – Problems Solved

What applications challenges can LWIR solve?

LWIR is the acronym, is it reminds us where on the electromagnetic spectrum we’re focused – wavelengths around 8 – 14 micrometers (8,000 – 14,000 nm). More descriptive is the term “thermal imaging”, which tells us we’re sensing temperatures not with a contact thermometer – but using non-contact sensors detecting emitted or radiated heat.

Remember COVID? Pre-screening for fever. Courtesy Teledyne DALSA.

Security, medical, fire detection, and environmental monitoring are common applications. More on applications further below. But first…

How does an LWIR camera work?

Most readers probably come to thermal imaging with some prior knowledge or experience in visible imaging. Forget all that! Well not all of it.

For visible imaging using CMOS sensors, photons enter pixel wells and generate a voltage. The array of adjacent pixels are read out as a digital representation of the scene passed through the lens and onto the sensor, according to the optics of the lens and the resolution of the sensor. Thermal camera sensors work differently!

Thermal cameras use a sensor that’s a microbolometer. The helpful part of the analogy to a CMOS sensor is there we still have an array of pixels, which determines the resolution of the camera, as a 2D digital representation of the scene’s thermal characteristics.

But unlike a CMOS sensor whose pixels react to photons, a microbolometers upper pixel surface, the detector, is comprised of IR absorbing material, such as Vanadium oxide. The detector is heated by the IR exposure, and the intensity of exposure in turn changes the electrical resistance. The change in electrical resistance is measured and passed by an electrode to a silicon substrate and readout integrated circuit.

Vanadium oxide (VOx) pixel structure – Courtesy Teledyne DALSA

Just as with visible imaging, for machine vision it’s the digital representation of the scene that matters, as it’s algorithms “consuming” the image in order to take some action: danger vs. safe; good part vs. bad part; steer left, straight, or right – or brake; etc. Whether one generates a pseudo-image for human consumption may well be unnecessary – or at least secondary.

Applications in LWIR

Applications include but are not limited to:

  • Security e.g. intrusion detection
  • Health screening e.g. sensing who has a fever
  • Fire detection – detect heat from early combustion before smoke is detectable
  • Building heat loss – for energy management and insulation planning
  • Equipment monitoring e.g. heat signature may reveal worn bearings or need for lubrication
  • Food safety – monitor whether required cooking temperatures attained before serving

You get the idea – if the thing you care about generates a heat signature distinct from the other things around it, thermal imaging may be just the thing.

What if I wanted to buy an LWIR camera?

We could help you with that. Does your application’s thermal range lie between -25C and +125C? Would a frame rate of 30fps do the job? Does a GigEVision interface appeal?

It’s likely we’d guide you to Teledyne DALSA’s Calibir GX cameras.

Calibir GX front and rear views – Courtesy Teledyne DALSA
Contact us

Precision of Teledyne DALSA Calibir GX cameras

Per factory calibration, one already gets precision to +/- 3 degrees Celsius. For more precision, use a black body radiator and manage your own calibration to +/- 0.5 degrees Celsius!

Thresholding with LUT

Sometimes one wants to emphasize only regions meeting certain criteria – in this case heat-based criteria. Consider the following image:

Everything between 38 and 41°C shown as red – Courtesy Teledyne DALSA

Teledyne DALSA Calibir GX control software let’s users define their own lookup tables (LUTs). One may optionally show regions meeting certain temperatures in color, leaving the rest of the image in monochrome.

Dynamic range

The “expressive power” of a camera is characterized by dynamic range. Just as the singers Enrico Caruso (opera) and Freddie Mercury (rock) were lauded for their range as well as their precision, in imaging we value dynamic range. Consider the image below of an electric heater element:

“Them” (left) vs. us (right) – Courtesy Teledyne DALSA

The left side of the image if from a 3rd party thermal imager – it’s pretty crude essentially showing just hot vs. not-hot, with no continuum. The right side was obtained with a Teledyne DALSA Calibir GX – there we see very hot, hot, warm, slightly warm, and cool – a helpfully nuanced range. Enabled by a 21 bit ADC, the Teledyne DALSA Calibir GX is capable of a dynamic range across 1500°C.

In this short blog we’ve called out just a few of the available features – call us at 978-474-0044 to tell us more about your application goals, and we can guide you to whichever hardware and software capabilities may be most helpful for you.

1st Vision’s sales engineers have over 100 years of combined experience to assist in your camera and components selection.  With a large portfolio of cameraslensescablesNIC cards and industrial computers, we can provide a full vision solution!

About you: We want to hear from you!  We’ve built our brand on our know-how and like to educate the marketplace on imaging technology topics…  What would you like to hear about?… Drop a line to info@1stvision.com with what topics you’d like to know more about. 

InfraRed (LWIR) Imaging used for fever screening

Teledyne Dalsa Calibir LWIR camera

Long Wave Infra Red (LWIR) cameras have been used for industrial applications to detect infrared light in the 8-14um wavelength region. This infrared light is invisible radiant energy that we experience as heat but can not see.   Applications for LWIR cameras continues to expand past industrial applications now entering into medical markets such as fever screening.

Teledyne Dalsa has expanded the Calibir LWIR camera series introducing the latest Calibir GXM model now with radiometric capabilities. With outbreaks of infectious diseases such as Covid 19, LWIR cameras can be used for fever screening by detecting elevated skin temperatures. Using optics, the cameras provide the ability to take the temperature of individuals keeping save distances between patients and medical practitioners.

Click HERE for a quote on the Calibir GXM LWIR camera

All cameras are factory-calibrated for reliable radiometric performance, have outstanding dynamic range and allow the best possible NETD over a vast range of temperature (>600C). . Coupled with many features such as multiple ROI, color maps, LUTs and the ability to sync and trigger multiple cameras, makes the Calbir GXM a good solution for many thermal imaging applications.

Image threshold
Example: Thresholding with Look Up Table (LUT) allows the Calibir GXM to mark certain temperatures with color while leaving the rest in monochrome.

Download the full Application note from Teledyne Dalsa HERE: “Thermal Imaging technology for fever screening”

Full specifications on Teledyne Dalsa LWIR cameras can be found HERE

Watch this 1 minute overview video

Need a full turnkey “Fever Detection System”? Contact our partners at Integro Technology. Click here to learn more

1st Vision’s sales engineers have over 100 years of combined experience to assist in your camera selection.  With a large portfolio of lenses, cables, NIC card and industrial computers, we can provide a full vision solution!

Previous related blogs:

Learn about Thermal Imaging – Problems solved with Dalsa’s new LWIR Calibir camera!