Please enable JavaScript to view this site.

IDS peak 2.8.0 / uEye+ firmware 3.33

Controls if the physical line is used as input or output.

Name

LineMode[LineSelector]

Category

DigitalIOControl

Interface

Enumeration

Access

Read/Write

Unit

-

Visibility

Expert

Values

Input
Output

Standard

SFNC

Availability uEye+

icon-gev icon-u3v

Availability uEye

icon-ui-gige icon-ui-usb2 icon-ui-usb3

Values description

Input: The selected physical line is used as input.

Output: The selected physical line is used as output.

hint_info

Depending on value set under LineSelector this register is read-only. LineMode can only be set for GPIOs.

Overview of available lines by camera family

This overview describes all available lines. Depending on the camera model used, not all functions may be supported.

Line

GigE uEye+ Warp10

GigE uEye+ CP Rev. 2/CP Rev. 2.2

GigE uEye+ FA/FA Rev. 1.2

GigE uEye+ SE Rev. 4/SE Rev. 4.2

USB 3 uEye+ CP Rev. 2/CP 2.2

uEye+ SE USB 3.1 Gen 1/SE Rev 1.2

uEye+ LE USB 3.1 Rev. 1.2 (PCB version only)

uEye+ XCP USB 3 Rev. 1.2

uEye+ XLE USB 3 Rev. 1.2 (PCB version only)

uEye+ XLS USB 3 Rev. 1.2

uEye+ XLE USB 3 Rev. 1.1 (PCB version only)

Line0

(Trigger) Input 0 with optocoupler

(Trigger) Input with optocoupler

(Trigger) Input without optocoupler

(Trigger) Input without optocoupler

Line1

(Trigger) Input 1 with optocoupler

(Flash) Output with optocoupler

(Flash) Output without optocoupler

(Flash) Output without optocoupler

Line2

(Trigger) Input 2 with optocoupler

GPIO 1 without optocoupler

GPIO 1 without optocoupler

-

Line3

(Flash) Output 0 with optocoupler

GPIO 2 without optocoupler

GPIO 2 without optocoupler

-

Line4

(Flash) Output 1 with optocoupler

-

-

-

Line5

Fast (Flash) Output 2 with optocoupler

-

-

-

Line6

Fast (Flash) Output 3 with optocoupler

-

-

-

Input: Physical input line that e.g. serves as trigger input (LineMode = "Input" only).

Output: Physical output line that e.g. serves as flash output (LineMode = "Output" only).

GPIO: Input or output line that can be used as input or output. To configure the line as input, change LineMode to "Input". To configure the line as output, change LineMode to "Output".

You will find information about the pin assignment and wiring of your camera either in the hardware descriptions of the respective camera family or in the model-specific data sheet.

Code example

C++

// Before accessing LineMode, make sure LineSelector is set correctly
// Set LineSelector to "Line2"
nodeMapRemoteDevice->FindNode<peak::core::nodes::EnumerationNode>("LineSelector")->SetCurrentEntry("Line2");
// Determine the current entry of LineMode
std::string value = nodeMapRemoteDevice->FindNode<peak::core::nodes::EnumerationNode>("LineMode")->CurrentEntry()->SymbolicValue();
// Get a list of all available entries of LineMode
auto allEntries = nodeMapRemoteDevice->FindNode<peak::core::nodes::EnumerationNode>("LineMode")->Entries();
std::vector<std::shared_ptr<peak::core::nodes::EnumerationEntryNode>> availableEntries;
for(const auto & entry : allEntries)
{
  if ((entry->AccessStatus()!=peak::core::nodes::NodeAccessStatus::NotAvailable)
          && (entry->AccessStatus()!=peak::core::nodes::NodeAccessStatus::NotImplemented))
  {
      availableEntries.emplace_back(entry);
  }
}

C#

// Before accessing LineMode, make sure LineSelector is set correctly
// Set LineSelector to "Line2"
nodeMapRemoteDevice.FindNode<peak.core.nodes.EnumerationNode>("LineSelector").SetCurrentEntry("Line2");
// Determine the current entry of LineMode
string value = nodeMapRemoteDevice.FindNode<peak.core.nodes.EnumerationNode>("LineMode").CurrentEntry().SymbolicValue();
// Get a list of all available entries of LineMode
allEntries = nodeMapRemoteDevice.FindNode<peak.core.nodes.EnumerationNode>("LineMode").Entries();
List<string> availableEntries = new List<string>();
for(int i = 0; i < allEntries.Count(); ++i)
{
  if ((allEntries[i].AccessStatus() != peak.core.nodes.NodeAccessStatus.NotAvailable)
          && (allEntries[i].AccessStatus() != peak.core.nodes.NodeAccessStatus.NotImplemented))
  {
      availableEntries.Add(allEntries[i].SymbolicValue());
  }
}

Python

# Before accessing LineMode, make sure LineSelector is set correctly
# Set LineSelector to "Line2" (str)
nodeMapRemoteDevice.FindNode("LineSelector").SetCurrentEntry("Line2")
# Determine the current entry of LineMode (str)
value = nodeMapRemoteDevice.FindNode("LineMode").CurrentEntry().SymbolicValue()
# Get a list of all available entries of LineMode
allEntries = nodeMapRemoteDevice.FindNode("LineMode").Entries()
availableEntries = []
for entry in allEntries:
  if (entry.AccessStatus() != ids_peak.NodeAccessStatus_NotAvailable
          and entry.AccessStatus() != ids_peak.NodeAccessStatus_NotImplemented):
      availableEntries.append(entry.SymbolicValue())

© 2024 IDS Imaging Development Systems GmbH