Please enable JavaScript to view this site.

IDS peak 2.20.0 / uEye+ firmware 3.80

IDS Peak comfortSDK, genericSDK, AFL, ICL, and IPL developer manuals are external documents.
Please contact us if you need these manuals.

The SignalMultiplierValue defines the number of internal signals that are generated within the period of the reference signal. The Reference Signal is defined in SignalMultiplierSource.

Name

SignalMultiplierValue[SignalMultiplierSelector]

Category

SignalMultiplierControl

Interface

Integer

Access

Read/Write

Unit

-

Visibility

Expert

Values

1 ... 128

Standard

IDS

Availability uEye+

icon-gev

Availability uEye

-

Code example

C++

// Determine the current SignalMultiplierValue
int64_t value = nodeMapRemoteDevice->FindNode<peak::core::nodes::IntegerNode>("SignalMultiplierValue")->Value();
// Set SignalMultiplierValue to 1
nodeMapRemoteDevice->FindNode<peak::core::nodes::IntegerNode>("SignalMultiplierValue")->SetValue(1);

C#

// Determine the current SignalMultiplierValue
long value = nodeMapRemoteDevice.FindNode<IDSImaging.Peak.API.Core.Nodes.IntegerNode>("SignalMultiplierValue").Value();
// Set SignalMultiplierValue to 1
nodeMapRemoteDevice.FindNode<IDSImaging.Peak.API.Core.Nodes.IntegerNode>("SignalMultiplierValue").SetValue(1);

Python

# Determine the current SignalMultiplierValue (int)
value = nodeMapRemoteDevice.FindNode("SignalMultiplierValue").Value()
# Set SignalMultiplierValue to 1 (int)
nodeMapRemoteDevice.FindNode("SignalMultiplierValue").SetValue(1)