IDS Peak comfortSDK, genericSDK, AFL, ICL, and IPL developer manuals are external documents.
Please contact us if you need these manuals.
The image could not be transferred via the USB bus.
Possible cause/remedy:
Not enough free bandwidth on the USB bus for transferring the image.
•Reduce the pixel clock.
•Operate fewer cameras at the same time on a USB bus.
•Check the quality of the cabling and components.
Name |
IS_CAP_STATUS_TRANSFER_FAILED |
Category |
|
Interface |
Integer |
Access |
Read |
Unit |
- |
Visibility |
Expert |
Values |
0 … 4294967295 Increment: 1 |
Standard |
IDS |
Availability uEye+ |
- |
Availability uEye |
|
Code example
C++
// Determine the current IS_CAP_STATUS_TRANSFER_FAILED
int64_t value = nodeMapDataStream->FindNode<peak::core::nodes::IntegerNode>("IS_CAP_STATUS_TRANSFER_FAILED")->Value();
C#
// Determine the current IS_CAP_STATUS_TRANSFER_FAILED
long value = nodeMapDataStream.FindNode<IDSImaging.Peak.API.Core.Nodes.IntegerNode>("IS_CAP_STATUS_TRANSFER_FAILED").Value();
Python
# Determine the current IS_CAP_STATUS_TRANSFER_FAILED (int)
value = nodeMapDataStream.FindNode("IS_CAP_STATUS_TRANSFER_FAILED").Value()