Please enable JavaScript to view this site.

IDS peak 2.20.0 / uEye+ firmware 3.80

IDS Peak comfortSDK, genericSDK, AFL, ICL, and IPL developer manuals are external documents.
Please contact us if you need these manuals.

The maximum allowable time for image capturing in the camera was exceeded.

Possible cause/remedy:
The selected timeout value for image capture is too low.

Reduce the exposure time.

Increase the timeout value.

Name

IS_CAP_STATUS_DEV_TIMEOUT

Category

UEYE_CAPTURE_STATUS

Interface

Integer

Access

Read

Unit

-

Visibility

Expert

Values

0 … 4294967295

Increment: 1

Standard

IDS

Availability uEye+

-

Availability uEye

icon-ui-gige icon-ui-usb2 icon-ui-usb3

Code example

C++

// Determine the current IS_CAP_STATUS_DEV_TIMEOUT
int64_t value = nodeMapDataStream->FindNode<peak::core::nodes::IntegerNode>("IS_CAP_STATUS_DEV_TIMEOUT")->Value();

C#

// Determine the current IS_CAP_STATUS_DEV_TIMEOUT
long value = nodeMapDataStream.FindNode<IDSImaging.Peak.API.Core.Nodes.IntegerNode>("IS_CAP_STATUS_DEV_TIMEOUT").Value();

Python

# Determine the current IS_CAP_STATUS_DEV_TIMEOUT (int)
value = nodeMapDataStream.FindNode("IS_CAP_STATUS_DEV_TIMEOUT").Value()